{"created":"2023-05-15T15:23:35.830194+00:00","id":10474,"links":{},"metadata":{"_buckets":{"deposit":"ad5aaac8-f71d-46b3-9696-2c1ca3a5b16d"},"_deposit":{"created_by":3,"id":"10474","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"10474"},"status":"published"},"_oai":{"id":"oai:sucra.repo.nii.ac.jp:00010474","sets":["94:429:434"]},"author_link":["17758"],"item_113_alternative_title_1":{"attribute_name":"タイトル(別言語)","attribute_value_mlt":[{"subitem_alternative_title":"Release mechanisms of airborne particles containing Japanese cedar pollen allergens and the measuring methods"}]},"item_113_biblio_info_9":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"20","bibliographicPageStart":"17","bibliographicVolumeNumber":"12","bibliographic_titles":[{}]}]},"item_113_date_35":{"attribute_name":"作成日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2008-03-06","subitem_date_issued_type":"Created"}]},"item_113_description_23":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The prevalence of Japanese cedar pollinosis has been increased. Japanese cedar pollen (JCP), which contains two allergens Cry j 1 and Cry j 2, belongs to coarse particles (particle diameter >2 μm). Some researchers showed that respirable-sized particles containing pollen allergen (particle diameter <2 μm) may be resuspended after light rainfall in the atmosphere. These particles may cause pollen asthma, however, release mechanisms of them are still uncertain. Therefore, it is important to examine release behaviour of Cry j 1 and Cry j 2 from JCP. The aim of this study is to found respirable-sized particles containing Cry j 1 and Cry j 2 (Cry j 1, Cry j 2 particles) in the atmosphere, to examine elution phenomenon of Cry j 1 from JCP and JCP burst followed by Cry j 2 release. Cry j 1 and Cry j 2 particles were collected size-selectively and were visualized by immunofluorescence technique. Consequently, Cry j 1 and Cry j 2 particles can be confirmed to resuspend in the atmosphere. The original solutions (OS) and the eluted solutions (ES) were prepared from mixture of JCP and artificial rain solution (ARS). The percentage of Cry j 1 concentration of ES to that of OS has already been exceeded 50 % within 1 hour after mixing. In contrast, pollen exposed to humidified air wasn’t burst. However, it is suggested that pollen burst with rainfall is due to osmotic pressure by rainfall. As a result, it was supposed that Cry j 1 and Cry j 2 particles might be generated from JCP which contacts rainfall. We propose to convert from pollen information to allergen information and to recommend avoidance of pollen asthma.","subitem_description_type":"Abstract"}]},"item_113_description_25":{"attribute_name":"注記","attribute_value_mlt":[{"subitem_description":"指導教員: 埼玉大学大学院理工学研究科准教授 王青躍","subitem_description_type":"Other"}]},"item_113_description_33":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"text","subitem_description_type":"Other"}]},"item_113_description_34":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_113_other_language_26":{"attribute_name":"その他の言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_113_publisher_11":{"attribute_name":"出版者名","attribute_value_mlt":[{"subitem_publisher":"埼玉大学大学院理工学研究科"}]},"item_113_record_name_8":{"attribute_name":"書誌","attribute_value_mlt":[{"subitem_record_name":"平成19年度環境制御システムコース修士論文発表会要旨集"}]},"item_113_text_3":{"attribute_name":"著者 ローマ字","attribute_value_mlt":[{"subitem_text_value":"KIRYU, Hiroki"}]},"item_113_text_36":{"attribute_name":"アイテムID","attribute_value_mlt":[{"subitem_text_value":"GM0000007"}]},"item_113_text_4":{"attribute_name":"著者 所属","attribute_value_mlt":[{"subitem_text_value":"埼玉大学大学院理工学研究科環境制御システムコース循環システム講座循環制御研究室"}]},"item_113_text_5":{"attribute_name":"著者 所属(別言語)","attribute_value_mlt":[{"subitem_text_value":"Graduate School of Science and Engineering, Saitama University"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"桐生, 浩希"},{"creatorName":"キリュウ, ヒロキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-01-23"}],"displaytype":"detail","filename":"GM0000007.pdf","filesize":[{"value":"820.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"GM0000007.pdf","url":"https://sucra.repo.nii.ac.jp/record/10474/files/GM0000007.pdf"},"version_id":"207169fa-7dba-4386-80b8-8b2c543315d5"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Japanese cedar pollen","subitem_subject_scheme":"Other"},{"subitem_subject":"allergen","subitem_subject_scheme":"Other"},{"subitem_subject":"pollen asthma","subitem_subject_scheme":"Other"},{"subitem_subject":"rainfall","subitem_subject_scheme":"Other"},{"subitem_subject":"release mechanism","subitem_subject_scheme":"Other"},{"subitem_subject":"allergen information","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"thesis","resourceuri":"http://purl.org/coar/resource_type/c_46ec"}]},"item_title":"スギ花粉アレルゲン含有粒子の放出機構とその計測手法に関する研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"スギ花粉アレルゲン含有粒子の放出機構とその計測手法に関する研究"}]},"item_type_id":"113","owner":"3","path":["434"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-03-07"},"publish_date":"2008-03-07","publish_status":"0","recid":"10474","relation_version_is_last":true,"title":["スギ花粉アレルゲン含有粒子の放出機構とその計測手法に関する研究"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-05-15T18:49:44.900764+00:00"}