@misc{oai:sucra.repo.nii.ac.jp:00010488, author = {山本, 恭子}, month = {}, note = {Recently, effects of low frequency magnetic fields to human health from power cables and electric appliances are worried, and many research and investigation of exposure of magnetic are studied. The strength of electromagnetic wave in the welding field is stronger than public environment. It was pointed out by European and American investigation. DIRECTIVE 2004/40/EC of the European Parliament and the Council was published. This directive is for the protection of workers from an electromagnetic field (EMF). Unfortunately, there is no standard concerning EMF in Japan. In near future, standards for protecting worker should be prepared. However, in working environment, especially in welding environment, it is difficult to evaluate magnetic field, since magnetic fields are complicated due to layout of welding cable and iron plates. Iron is a ferromagnetic material. The magnetic flux is intended to pass in to ferromagnetic materials. In this study, the effect of magnetic fields from iron plates is investigated by numerical simulation and measurement., 指導教員: 埼玉大学大学院理工学研究科准教授 山根敏, text, application/pdf}, title = {電気溶接作業環境における低周波磁界の数値解析と実測}, year = {2008}, yomi = {ヤマモト, ヤスコ} }