@article{oai:sucra.repo.nii.ac.jp:00012778, author = {塩崎, 孝壽 and 川橋, 正昭 and 鈴木, 允}, issue = {477}, journal = {日本機械学會論文集. B編}, month = {}, note = {The condensation of SF_6 carried in Ar has been studied experimentally in supersonic nozzle flow, and also experimental data was compared with numerical calculation based on nucleation and drop-growth theory. It was found that the static pressure and static temperature distribution in the nozzle and the onset point of SF_6 condensation were affected by differences of the physical properties at temperatures above and below the transition point of SF_6. When the stagnation pressure was lower than or equal to 50 KPa, the onset point of SF_6 condensation was found to be distributed in the region far distant from the saturation line of SF_6 or below the transition temperature of SF_6., text, application/pdf}, pages = {2202--2206}, title = {凝縮を伴う超音速噴流 : 第3報, SF_6の転移温度の影響}, volume = {52}, year = {1986}, yomi = {シオザキ, コウジュ and カワハシ, マサアキ and スズキ, マコト} }