{"created":"2023-05-15T15:26:05.165123+00:00","id":13961,"links":{},"metadata":{"_buckets":{"deposit":"cb13f30a-f404-4227-92d1-15885a507bdb"},"_deposit":{"created_by":3,"id":"13961","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"13961"},"status":"published"},"_oai":{"id":"oai:sucra.repo.nii.ac.jp:00013961","sets":["96:641"]},"author_link":["23763","23765","23764","23762"],"item_119_alternative_title_1":{"attribute_name":"タイトル(別言語)","attribute_value_mlt":[{"subitem_alternative_title":"Evaluation of Dynamic Response of the New Closed Infusion System for Direct Pressure Measurement"}]},"item_119_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"375","bibliographicPageStart":"370","bibliographicVolumeNumber":"76","bibliographic_titles":[{"bibliographic_title":"医科器械学"},{"bibliographic_title":"The Japanese journal of medical instrumentation","bibliographic_titleLang":"en"}]}]},"item_119_date_31":{"attribute_name":"作成日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2009-09-14","subitem_date_issued_type":"Created"}]},"item_119_description_19":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We evaluated the dynamic response of the closed type three way stopcock (SAS, Tyco Healthcare, USA). One of its ports is closed with rubber septum and used as an airtight sealed infusion port in order to prevent infection. The pressure wave passes through a duct in the shape of semicircle, and across a small chamber behind the rubber septum. It is feared that this passage may have damaging effects on pressure wave propagation. We measured the frequency characteristics of the stopcock, resulting in the highest frequency (fh) to be 1-1.5 Hz higher than that of conventional three way stopcocks. This means that the unique structure adopted in this stopcock did not affect on the frequency characteristics. But, there remained a slight concern about temperature dependency due to air bubbles caught in the small chamber behind the septum.","subitem_description_type":"Abstract"}]},"item_119_description_21":{"attribute_name":"注記","attribute_value_mlt":[{"subitem_description":"rights: 日本医療機器学会\nrights: 本文データは学協会の許諾に基づきCiNiiから複製したものである\nrelation: IsVersionOf: http://ci.nii.ac.jp/naid/110004749524/","subitem_description_type":"Other"}]},"item_119_description_29":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"text","subitem_description_type":"Other"}]},"item_119_description_30":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_119_other_language_22":{"attribute_name":"その他の言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_119_publisher_11":{"attribute_name":"出版者名","attribute_value_mlt":[{"subitem_publisher":"日本医療機器学会"}]},"item_119_source_id_14":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385440X","subitem_source_identifier_type":"ISSN"}]},"item_119_text_27":{"attribute_name":"版","attribute_value_mlt":[{"subitem_text_value":"[出版社版]"}]},"item_119_text_3":{"attribute_name":"著者 ローマ字","attribute_value_mlt":[{"subitem_text_value":"Ito, Shinya"},{"subitem_text_value":"Hasegawa, Shinya"},{"subitem_text_value":"Shimada, Masato"},{"subitem_text_value":"Kinefuchi, Yoshio"}]},"item_119_text_32":{"attribute_name":"アイテムID","attribute_value_mlt":[{"subitem_text_value":"A1003380"}]},"item_119_text_4":{"attribute_name":"著者 所属","attribute_value_mlt":[{"subitem_text_value":"東海大学大学院開発工学研究科医用 生体工学専攻"},{"subitem_text_value":"東海大学大学院開発工学研究科医用 生体工学専攻"},{"subitem_text_value":"埼玉大学大学院理工学研究科情報数理科学専攻"},{"subitem_text_value":"東海大学大学院開発工学研究科医用 生体工学専攻"}]},"item_119_text_5":{"attribute_name":"著者 所属(別言語)","attribute_value_mlt":[{"subitem_text_value":"Department of Biomedical Engineering, Graduate School of High-Technology for Human Welfare, Tokai University"},{"subitem_text_value":"Department of Biomedical Engineering, Graduate School of High-Technology for Human Welfare, Tokai University"},{"subitem_text_value":"Department of Information and Mathematical Sciences, Graduate School of Science and Engineering, Saitama University"},{"subitem_text_value":"Department of Biomedical Engineering, Graduate School of High-Technology for Human Welfare, Tokai University"}]},"item_119_text_9":{"attribute_name":"年月次","attribute_value_mlt":[{"subitem_text_value":"2006-6"}]},"item_119_version_type_28":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"伊藤, 真也"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"長谷川, 晋也"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"嶋田, 勝斗"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"杵淵, 嘉夫"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-01-24"}],"displaytype":"detail","filename":"A1003380.pdf","filesize":[{"value":"774.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"A1003380.pdf","url":"https://sucra.repo.nii.ac.jp/record/13961/files/A1003380.pdf"},"version_id":"96803dad-13a9-448c-9066-6183c877d35a"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"閉鎖式輸液ラインを用いた直接動脈圧測定とそのダイナミックレスポンスの評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"閉鎖式輸液ラインを用いた直接動脈圧測定とそのダイナミックレスポンスの評価"}]},"item_type_id":"119","owner":"3","path":["641"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-09-14"},"publish_date":"2009-09-14","publish_status":"0","recid":"13961","relation_version_is_last":true,"title":["閉鎖式輸液ラインを用いた直接動脈圧測定とそのダイナミックレスポンスの評価"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-05-16T12:17:37.658819+00:00"}