{"created":"2023-05-15T15:26:45.610200+00:00","id":14892,"links":{},"metadata":{"_buckets":{"deposit":"202c26ab-26bb-4e39-bdf8-82a67f3137a5"},"_deposit":{"created_by":3,"id":"14892","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"14892"},"status":"published"},"_oai":{"id":"oai:sucra.repo.nii.ac.jp:00014892","sets":["95:240:496:493"]},"author_link":["25177"],"item_120_alternative_title_1":{"attribute_name":"タイトル(別言語)","attribute_value_mlt":[{"subitem_alternative_title":"Characteristics of High Resolution ICP-MS"}]},"item_120_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2000","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"86","bibliographicPageStart":"80","bibliographicVolumeNumber":"20","bibliographic_titles":[{"bibliographic_title":"CACS FORUM"}]}]},"item_120_date_31":{"attribute_name":"作成日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2010-01-06","subitem_date_issued_type":"Created"}]},"item_120_description_19":{"attribute_name":"概要","attribute_value_mlt":[{"subitem_description":"At present, there are two kind of the instruments of ICP-MS. One is HR-ICP-MS that used double focusing mass spectrometer the other one is Q-ICP-MS that used a quadrupole mass spectrometer. HR-ICP-MS has many characteristics in comparison with Q-ICP-MS. It is reported of the HR-ICP-MS structure and characteristics and also reported one of the examples of the measurement that made the most of the characteristic of it’s high resolving power in this time.\n\n概要:現在,一般的に使用されているICP-MS にはその分光器に四重極形質量分析計用いたQ-ICP-MS と二重収束形質量分析計を用いたHR-ICP-MS がある.HR-ICP-MS は一般に高分解能ICP-MS と呼ばれており,Q-ICP-MS と比較して数々の特徴を有している.今回は,この高分解能ICP-MS の構造と特徴,またその特徴を活かした測定の例を報告する.","subitem_description_type":"Other"}]},"item_120_description_29":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"text","subitem_description_type":"Other"}]},"item_120_description_30":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_120_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24561/00014886","subitem_identifier_reg_type":"JaLC"}]},"item_120_publisher_11":{"attribute_name":"出版者名","attribute_value_mlt":[{"subitem_publisher":"埼玉大学分析センター"}]},"item_120_text_27":{"attribute_name":"版","attribute_value_mlt":[{"subitem_text_value":"[出版社版]"}]},"item_120_text_3":{"attribute_name":"著者 ローマ字","attribute_value_mlt":[{"subitem_text_value":"ISHII, Kiyotaka"}]},"item_120_text_32":{"attribute_name":"アイテムID","attribute_value_mlt":[{"subitem_text_value":"KY-AN10402595-20-14"}]},"item_120_text_4":{"attribute_name":"著者 所属","attribute_value_mlt":[{"subitem_text_value":"日本電子株式会社分析機器技術本部研究開発部MSグループ"}]},"item_120_text_5":{"attribute_name":"著者 所属(別言語)","attribute_value_mlt":[{"subitem_text_value":"JEOL LTD. Analytical Instrument Division MS Group"}]},"item_120_text_9":{"attribute_name":"年月次","attribute_value_mlt":[{"subitem_text_value":"2000-11"}]},"item_120_version_type_28":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"石井, 清孝"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-01-24"}],"displaytype":"detail","filename":"KY-AN10402595-20-14.pdf","filesize":[{"value":"382.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KY-AN10402595-20-14.pdf","url":"https://sucra.repo.nii.ac.jp/record/14892/files/KY-AN10402595-20-14.pdf"},"version_id":"a5b569ff-fd71-411b-aaa7-6e0ec75729d5"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"高分解能ICP-MSの特徴とその測定例<総説 レビュー>","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"高分解能ICP-MSの特徴とその測定例<総説 レビュー>"}]},"item_type_id":"120","owner":"3","path":["493"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-11-12"},"publish_date":"2009-11-12","publish_status":"0","recid":"14892","relation_version_is_last":true,"title":["高分解能ICP-MSの特徴とその測定例<総説 レビュー>"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-05-15T17:48:31.318583+00:00"}