@article{oai:sucra.repo.nii.ac.jp:00016488, author = {加藤, 寛 and 松浦, 誠}, journal = {埼玉大学地域オープンイノベーションセンター紀要, Report of Comprehensive Open Innovation Center, Saitama University}, month = {}, note = {The ultrasonic measurement was carried out to detect porosities in aluminum alloy base composite castings (MMC-Casts) produced by hybrid method of the sand-mold casting and the low pressure casting. Irradiation of the ultrasonic wave with a frequency of 5 MHz and 20 MHz showed that the ultrasonic wave propagated to the bottom of the specimen of 10 mm in thickness with large scatter from SiC particles distributed in MMC-Casts. By using the Al-Cu alloy castings with a thickness of 19 mm, artificial holes of different diameter were measured from the other side, and a hole of 1 mm in diameter was detected with the ultrasonic wave of a frequency of 5 MHz., text, application/pdf}, pages = {78--78}, title = {アルミ基複合材料鋳物のハイブリッド砂型鋳造法の開発}, volume = {1}, year = {2009}, yomi = {カトウ, ヒロシ} }