{"created":"2023-05-15T15:28:33.918786+00:00","id":17724,"links":{},"metadata":{"_buckets":{"deposit":"2d9f15d6-a8f5-4eb9-a42a-3386e9d6453d"},"_deposit":{"created_by":3,"id":"17724","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"17724"},"status":"published"},"_oai":{"id":"oai:sucra.repo.nii.ac.jp:00017724","sets":["84:291:319"]},"author_link":["28439","18104","18099"],"item_120_alternative_title_1":{"attribute_name":"タイトル(別言語)","attribute_value_mlt":[{"subitem_alternative_title":"Controlling Resonance Frequency of Cavity by Monitoring Incident Light Intensity"}]},"item_120_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"204","bibliographicPageStart":"195","bibliographicVolumeNumber":"63","bibliographic_titles":[{"bibliographic_title":"埼玉大学紀要. 教育学部"},{"bibliographic_title":"Journal of Saitama University. Faculty of Education","bibliographic_titleLang":"en"}]}]},"item_120_date_31":{"attribute_name":"作成日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2014-10-28","subitem_date_issued_type":"Created"}]},"item_120_description_19":{"attribute_name":"概要","attribute_value_mlt":[{"subitem_description":"We developed a novel technique for controlling the resonance frequency of a cavity that is maintained even when the incident light intensity fluctuates. To achieve this, we produced a circuit to generate an error signal for controlling the cavity length that subtracts the signal monitoring the incident light intensity from that monitoring the transmitted light intensity. With a conventional feedback circuit, the resonance frequency of a confocal Fabry-Perot cavity was stabilized when the incident light intensity was greater than or equal to 40% of the initial intensity. By combining the conventional feedback circuit with our subtraction circuit mentioned above, we demonstrated that we could stabilize the resonance frequency even when the incident light intensity was decreased to 5% of the initial one. Our technique is applicable to the long-term stabilization of a cavity that has complex structures like an external enhancement cavity for the frequency doubling of the laser light.","subitem_description_type":"Other"}]},"item_120_description_29":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"text","subitem_description_type":"Other"}]},"item_120_description_30":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_120_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24561/00017718","subitem_identifier_reg_type":"JaLC"}]},"item_120_publisher_11":{"attribute_name":"出版者名","attribute_value_mlt":[{"subitem_publisher":"埼玉大学教育学部"}]},"item_120_publisher_12":{"attribute_name":"出版者名(別言語)","attribute_value_mlt":[{"subitem_publisher":"Faculty of Education, Saitama University"}]},"item_120_source_id_14":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"18815146","subitem_source_identifier_type":"ISSN"}]},"item_120_text_27":{"attribute_name":"版","attribute_value_mlt":[{"subitem_text_value":"[出版社版]"}]},"item_120_text_3":{"attribute_name":"著者 ローマ字","attribute_value_mlt":[{"subitem_text_value":"IIDA, Katsuya"},{"subitem_text_value":"KONDO, Hitoshi"},{"subitem_text_value":"OHMUKAI, Ryuzo"}]},"item_120_text_32":{"attribute_name":"アイテムID","attribute_value_mlt":[{"subitem_text_value":"KY-AA12318206-6302-14"}]},"item_120_text_4":{"attribute_name":"著者 所属","attribute_value_mlt":[{"subitem_text_value":"埼玉大学教育学部理科教育講座"},{"subitem_text_value":"埼玉大学教育学部理科教育講座"},{"subitem_text_value":"埼玉大学教育学部理科教育講座"}]},"item_120_text_5":{"attribute_name":"著者 所属(別言語)","attribute_value_mlt":[{"subitem_text_value":"Faculty of Education, Saitama University"},{"subitem_text_value":"Faculty of Education, Saitama University"},{"subitem_text_value":"Faculty of Education, Saitama University"}]},"item_120_text_9":{"attribute_name":"年月次","attribute_value_mlt":[{"subitem_text_value":"2014"}]},"item_120_version_type_28":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"飯田, 克也"},{"creatorName":"イイダ, カツヤ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"近藤, 一史"},{"creatorName":"コンドウ, ヒトシ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"大向, 隆三"},{"creatorName":"オオムカイ, リュウゾウ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-01-25"}],"displaytype":"detail","filename":"KY-AA12318206-6302-14.pdf","filesize":[{"value":"1.8 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KY-AA12318206-6302-14.pdf","url":"https://sucra.repo.nii.ac.jp/record/17724/files/KY-AA12318206-6302-14.pdf"},"version_id":"1f0c03d9-66b4-4672-96c5-17c9d63ad7f4"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"光学共振器","subitem_subject_scheme":"Other"},{"subitem_subject":"共鳴周波数","subitem_subject_scheme":"Other"},{"subitem_subject":"安定化制御","subitem_subject_scheme":"Other"},{"subitem_subject":"光強度補償","subitem_subject_scheme":"Other"},{"subitem_subject":"cavity","subitem_subject_scheme":"Other"},{"subitem_subject":"resonance frequency","subitem_subject_scheme":"Other"},{"subitem_subject":"stabilization","subitem_subject_scheme":"Other"},{"subitem_subject":"compensation for intensity fluctuation","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"強度モニターを利用した共振器の制御方法の開発<数学・自然科学>","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"強度モニターを利用した共振器の制御方法の開発<数学・自然科学>"}]},"item_type_id":"120","owner":"3","path":["319"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-10-29"},"publish_date":"2014-10-29","publish_status":"0","recid":"17724","relation_version_is_last":true,"title":["強度モニターを利用した共振器の制御方法の開発<数学・自然科学>"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-05-15T17:29:59.842355+00:00"}