WEKO3
アイテム
{"_buckets": {"deposit": "1572d9b5-f916-47e5-bb44-5c7799ae92c3"}, "_deposit": {"created_by": 3, "id": "12635", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "12635"}, "status": "published"}, "_oai": {"id": "oai:sucra.repo.nii.ac.jp:00012635", "sets": ["426"]}, "author_link": ["16507", "16698", "19696", "19695"], "item_119_alternative_title_1": {"attribute_name": "タイトル(別言語)", "attribute_value_mlt": [{"subitem_alternative_title": "Development of Ultrasonic Dental Scaler with A Diagnosis Function"}]}, "item_119_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "721", "bibliographicPageEnd": "2731", "bibliographicPageStart": "2727", "bibliographicVolumeNumber": "72", "bibliographic_titles": [{"bibliographic_title": "日本機械学會論文集. C編"}]}]}, "item_119_date_31": {"attribute_name": "作成日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2007-03-05", "subitem_date_issued_type": "Created"}]}, "item_119_description_19": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "An ultrasonic dental sealer is an equipment to remove dental calculi from teeth. A conventional sealer consists of handpiece with a Langevin type ultrasonic transducer and a driver circuit to vibrate at resonance frequency. The transducer has a horn to enhance vibration and a tip to scale the calculi. On the back of the transducer, a rubber hose is connected to supply water to the scaling points. Such a transducer has two problems. One is vibration damping due to the water hose. The other is resonance frequency shift according to contact load on the tip. Two types of transducer are fabricated to compare influence of the hose connecting method. Measuring electric Q factor with water flowing, side connection seems to decrease the damping rather than back connection. A new transducer is designed based on the comparison result. To trace the frequency shift, we develop a resonance trace system. Arranging operating frequency based on detected current phase, the system can trace mechanical resonance with time delay of 17ms. We also propose teeth diagnosis using the resonance trace system. Observing the resonance frequency shift when the tip contacts a material, stiffness of the material can be estimated. The shift comparison result between a damaged tooth and a fine tooth shows possibility of dental caries diagnosis.", "subitem_description_type": "Abstract"}]}, "item_119_description_29": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "text", "subitem_description_type": "Other"}]}, "item_119_description_30": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_119_publisher_11": {"attribute_name": "出版者名", "attribute_value_mlt": [{"subitem_publisher": "社団法人日本機械学会"}]}, "item_119_relation_7": {"attribute_name": "著者 外部リンク", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "\u0026EMPTY\u0026"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "\u0026EMPTY\u0026", "subitem_relation_type_select": "URI"}}, {"subitem_relation_name": [{"subitem_relation_name_text": "http://s-read.saitama-u.ac.jp/researchers/pages/researcher/QuhxsNBx"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://s-read.saitama-u.ac.jp/researchers/pages/researcher/QuhxsNBx", "subitem_relation_type_select": "URI"}}, {"subitem_relation_name": [{"subitem_relation_name_text": "\u0026EMPTY\u0026"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "\u0026EMPTY\u0026", "subitem_relation_type_select": "URI"}}, {"subitem_relation_name": [{"subitem_relation_name_text": "http://s-read.saitama-u.ac.jp/researchers/pages/researcher/aNgZdKoZ"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://s-read.saitama-u.ac.jp/researchers/pages/researcher/aNgZdKoZ", "subitem_relation_type_select": "URI"}}]}, "item_119_source_id_14": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "03875024", "subitem_source_identifier_type": "ISSN"}]}, "item_119_text_27": {"attribute_name": "版", "attribute_value_mlt": [{"subitem_text_value": "[出版社版]"}]}, "item_119_text_3": {"attribute_name": "著者 ローマ字", "attribute_value_mlt": [{"subitem_text_value": "MARUYAMA, Yutaka"}, {"subitem_text_value": "TAKASAKI, Masaya"}, {"subitem_text_value": "KUTAMI, Tomonori"}, {"subitem_text_value": "MIZUNO, Takeshi"}]}, "item_119_text_32": {"attribute_name": "アイテムID", "attribute_value_mlt": [{"subitem_text_value": "A3000006"}]}, "item_119_text_35": {"attribute_name": "公開日(XooNIps)", "attribute_value_mlt": [{"subitem_text_value": "Jul 10, 2007 09:00:00"}]}, "item_119_text_36": {"attribute_name": "最終更新日(XooNIps)", "attribute_value_mlt": [{"subitem_text_value": "Sep 2, 2009 14:51:12"}]}, "item_119_text_37": {"attribute_name": "更新履歴(XooNIps)", "attribute_value_mlt": [{"subitem_text_value": "Sep 2, 2009 著者 を変更"}, {"subitem_text_value": "Aug 4, 2009 フリーキーワード, 本文, 著者 を変更"}, {"subitem_text_value": "Mar 18, 2009 フリーキーワード, キーワード を変更"}, {"subitem_text_value": "Oct 14, 2008 フリーキーワード, インデックス, キーワード を変更"}, {"subitem_text_value": "Mar 5, 2008 フリーキーワード, 本文, キーワード を変更"}, {"subitem_text_value": "Mar 5, 2008 フリーキーワード, インデックス, 版, 本文, キーワード を変更"}, {"subitem_text_value": "Feb 21, 2008 フリーキーワード, インデックス, 上位タイトル, キーワード を変更"}, {"subitem_text_value": "Oct 20, 2007 フリーキーワード, インデックス, アクセス条件, キーワード, 言語, ISSN を変更"}, {"subitem_text_value": "Jul 26, 2007 フリーキーワード, 本文, キーワード を変更"}, {"subitem_text_value": "Jul 11, 2007 フリーキーワード, キーワード を変更"}, {"subitem_text_value": "Jul 10, 2007 フリーキーワード, インデックス, 抄録, キーワード を変更"}, {"subitem_text_value": "Jul 10, 2007 ID, フリーキーワード, インデックス, キーワード を変更"}]}, "item_119_text_38": {"attribute_name": "登録者(XooNIps)", "attribute_value_mlt": [{"subitem_text_value": "sucra_jim4"}]}, "item_119_text_39": {"attribute_name": "閲覧数(XooNIps)", "attribute_value_mlt": [{"subitem_text_value": "1416"}]}, "item_119_text_4": {"attribute_name": "著者 所属", "attribute_value_mlt": [{"subitem_text_value": "埼玉大学大学院理工学研究科"}]}, "item_119_text_40": {"attribute_name": "ダウンロード数(XooNIps)", "attribute_value_mlt": [{"subitem_text_value": "1132"}]}, "item_119_text_41": {"attribute_name": "XooNIps_インデックス", "attribute_value_mlt": [{"subitem_text_value": "sucra_jim4|Public/埼玉大学/理工学研究科|Public/埼玉大学/理工学研究科/人間支援・生産科学部門|Public/主題別/工学/機械工学/機械力学・制御|Public/ジャンル別/学術雑誌論文(国内)/日本機械学会"}]}, "item_119_text_42": {"attribute_name": "XooNIps_ITEM_KEY", "attribute_value_mlt": [{"subitem_text_value": "497"}]}, "item_119_text_5": {"attribute_name": "著者 所属(別言語)", "attribute_value_mlt": [{"subitem_text_value": "Graduate School of Science and Engineering, Saitama University"}]}, "item_119_text_9": {"attribute_name": "年月次", "attribute_value_mlt": [{"subitem_text_value": "2006-09"}]}, "item_119_version_type_28": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "丸山, 裕"}, {"creatorName": "マルヤマ, ユタカ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "19695", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高崎, 正也"}, {"creatorName": "タカサキ, マサヤ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "16698", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "QuhxsNBx", "nameIdentifierScheme": "研究者総覧", "nameIdentifierURI": "http://s-read.saitama-u.ac.jp/researchers/pages/researcher/QuhxsNBx"}]}, {"creatorNames": [{"creatorName": "久田見, 朋範"}, {"creatorName": "クタニ, トモノリ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "19696", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "水野, 毅"}, {"creatorName": "ミズノ, タケシ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "16507", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-01-24"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "A3000006.pdf", "filesize": [{"value": "613.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 613900.0, "url": {"label": "A3000006.pdf", "url": "https://sucra.repo.nii.ac.jp/record/12635/files/A3000006.pdf"}, "version_id": "93eaefc3-fec9-420a-b3aa-c13f222658be"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Supersonic Wave", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Piezo-Element", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Mesurement", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Frequency Tracing", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Dental Equipment", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "診断機能を備えた歯科用超音波スケーラの開発(\u003c小特集\u003e運動と振動の制御の21世紀への新展開)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "診断機能を備えた歯科用超音波スケーラの開発(\u003c小特集\u003e運動と振動の制御の21世紀への新展開)"}]}, "item_type_id": "119", "owner": "3", "path": ["426"], "permalink_uri": "https://sucra.repo.nii.ac.jp/records/12635", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-07-10"}, "publish_date": "2007-07-10", "publish_status": "0", "recid": "12635", "relation": {}, "relation_version_is_last": true, "title": ["診断機能を備えた歯科用超音波スケーラの開発(\u003c小特集\u003e運動と振動の制御の21世紀への新展開)"], "weko_shared_id": -1}
診断機能を備えた歯科用超音波スケーラの開発(<小特集>運動と振動の制御の21世紀への新展開)
https://sucra.repo.nii.ac.jp/records/12635
https://sucra.repo.nii.ac.jp/records/12635aafe0644-f4d7-4f7a-999d-dbde1433353a
名前 / ファイル | ライセンス | アクション |
---|---|---|
A3000006.pdf (613.9 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-07-10 | |||||
タイトル | ||||||
タイトル | 診断機能を備えた歯科用超音波スケーラの開発(<小特集>運動と振動の制御の21世紀への新展開) | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Supersonic Wave | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Piezo-Element | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Mesurement | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Frequency Tracing | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Dental Equipment | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
タイトル(別言語) | ||||||
その他のタイトル | Development of Ultrasonic Dental Scaler with A Diagnosis Function | |||||
著者 |
丸山, 裕
× 丸山, 裕× 高崎, 正也× 久田見, 朋範× 水野, 毅 |
|||||
著者 ローマ字 | ||||||
MARUYAMA, Yutaka | ||||||
著者 ローマ字 | ||||||
TAKASAKI, Masaya | ||||||
著者 ローマ字 | ||||||
KUTAMI, Tomonori | ||||||
著者 ローマ字 | ||||||
MIZUNO, Takeshi | ||||||
著者 所属 | ||||||
埼玉大学大学院理工学研究科 | ||||||
著者 所属(別言語) | ||||||
Graduate School of Science and Engineering, Saitama University | ||||||
書誌情報 |
日本機械学會論文集. C編 巻 72, 号 721, p. 2727-2731, 発行日 2006 |
|||||
年月次 | ||||||
2006-09 | ||||||
出版者名 | ||||||
出版者 | 社団法人日本機械学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 03875024 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | An ultrasonic dental sealer is an equipment to remove dental calculi from teeth. A conventional sealer consists of handpiece with a Langevin type ultrasonic transducer and a driver circuit to vibrate at resonance frequency. The transducer has a horn to enhance vibration and a tip to scale the calculi. On the back of the transducer, a rubber hose is connected to supply water to the scaling points. Such a transducer has two problems. One is vibration damping due to the water hose. The other is resonance frequency shift according to contact load on the tip. Two types of transducer are fabricated to compare influence of the hose connecting method. Measuring electric Q factor with water flowing, side connection seems to decrease the damping rather than back connection. A new transducer is designed based on the comparison result. To trace the frequency shift, we develop a resonance trace system. Arranging operating frequency based on detected current phase, the system can trace mechanical resonance with time delay of 17ms. We also propose teeth diagnosis using the resonance trace system. Observing the resonance frequency shift when the tip contacts a material, stiffness of the material can be estimated. The shift comparison result between a damaged tooth and a fine tooth shows possibility of dental caries diagnosis. | |||||
版 | ||||||
[出版社版] | ||||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | text | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
作成日 | ||||||
日付 | 2007-03-05 | |||||
日付タイプ | Created | |||||
アイテムID | ||||||
A3000006 |